What is an inert gas system on a tanker and why is it needed?
An inert gas system fills a tanker's cargo tanks with low-oxygen gas so the vapour inside cannot burn, keeping tank oxygen at 8% by volume or less.
Updated 2026-11-09
Answer
An inert gas system (IGS) supplies a tanker's cargo tanks with gas that contains too little oxygen to support combustion. Oil and many chemical cargoes give off flammable vapour, and a tank holding that vapour mixed with air can explode if a spark from static, a metal impact or hot work reaches it. Inert gas lowers the oxygen content below the level needed for combustion, so the tank atmosphere cannot burn.
In detail
The rules are in SOLAS chapter II-2 and chapter 15 of the Fire Safety Systems (FSS) Code. The system must be able to deliver gas with no more than 5% oxygen by volume and keep the tank atmosphere at no more than 8% oxygen, under positive pressure at all times so that air cannot leak in. For tankers built on or after 1 January 2016 that carry crude oil or petroleum products with a flashpoint of 60 degrees C or less, an IGS is required at 8,000 tonnes deadweight and above. Before that the threshold was 20,000 tonnes deadweight. Chemical tankers of that size built from that date also need one when carrying low-flashpoint cargoes, whatever their tank size, although older chemical tankers could be exempted.
The gas comes from one of three sources:
- boiler flue gas, which is already low in oxygen, cleaned and cooled before use
- an inert gas generator, which burns diesel oil specifically to make inert gas
- a nitrogen generator, used on many chemical tankers, which separates nitrogen from compressed air
In a flue gas system the gas passes through a scrubber that cools it and washes out soot and sulphur compounds, then blowers drive it into the deck main. A deck water seal and a non-return valve stop cargo vapour flowing back towards the machinery spaces when the blowers stop. Pressure/vacuum valves and a pressure/vacuum breaker protect the tanks from overpressure and from vacuum. Oxygen content and pressure are monitored continuously, alarms sound if the oxygen content of the supply rises too high, and the supply is shut off automatically at a higher limit.
The IGS is used throughout the cargo cycle. Tanks are inerted before loading. During discharge the blowers replace the outgoing cargo with inert gas, which is why the system must be able to supply at least 125% of the maximum discharge rate. Crude oil washing may only be done in inerted tanks. On the ballast passage the tanks are topped up to hold their pressure. Before anyone enters a tank, it is purged with inert gas to bring the hydrocarbon content down, then gas-freed with fresh air and tested.
The usual problems are high oxygen in the supply, often from poor boiler combustion or a faulty analyser, a deck seal that has lost its water, and tank pressure falling during discharge because the inert gas supply cannot keep up with the cargo pumps. Cargo operations stop until the cause is put right. Officers check individual tanks with portable oxygen meters, because a reading in the main does not prove that every tank is below 8%.
Related Terms
Continue Reading
More Questions in Shipboard Operations
An engine-room round compares readings, sounds and smells with normal values for the current load, logs real figures and spots trends before alarms do.
A toolbox talk is a short safety briefing at the job site before work starts, held before higher-risk work and repeated whenever the job or conditions change.
The core precautions before entering an enclosed space — atmosphere testing, permit, ventilation, standby and communications — because these spaces still kill seafarers.
Safe bunkering means an agreed plan and checklist, deck prepared against spills, close watch at topping off, a MARPOL sample and checked delivery figures.