Skip to content
Blog

What Is The Function Of An Eductor On A Ship?

The function of an eductor on a ship is to use a jet of motive fluid, usually seawater or air, to create a vacuum by the Venturi effect and draw liquid, gas or sludge out of a compartment.

Marine Insight 360· Published · Updated · 5 min read
What Is The Function Of An Eductor On A Ship?
What Is The Function Of An Eductor On A Ship?

The function of an eductor on a ship is to use a jet of motive fluid, usually seawater or air, to create a vacuum by the Venturi effect and draw liquid, gas or sludge out of a compartment.

An eductor is a simple jet pump that uses the Venturi effect to move air, gas or liquid out of a space. It has no moving parts and needs only a supply of motive fluid to work, so it can be used anywhere on a ship, including hazardous areas. When enough motive fluid passes through the eductor (the amount depends on its design), it creates a low pressure inside it. That vacuum lets the eductor draw liquid or gas from the space being emptied, and the mixture leaves through the discharge outlet together with the motive fluid.

What Are Eductors Used For?

Eductors are used across many industries as a cheap alternative to centrifugal pumps. They can move slurries and granular solids, mix liquids, create a vacuum, agitate tank contents and pump liquids. Because they are inexpensive and have no moving parts, they are often used as the main means of pumping in hazardous areas.

On ships they are used to prime centrifugal pumps, to strip ballast tanks, in vacuum toilet systems, to maintain the vacuum in fresh water generators, and to pump out sludge and tank residues on tankers.

How Ship Eductors Work

Eductors work on Bernoulli's principle, which says that when the velocity of a fluid increases, its pressure falls. For an incompressible fluid flowing along a horizontal streamline, the simplified Bernoulli equation is:

p + ½ρv² = constant

Where,

v = velocity of the liquid,

p = pressure of the liquid, and

ρ = density of the liquid.

So as velocity rises, pressure falls, and the other way round. The equation is really a statement of conservation of energy. Now consider a steady flow of liquid through a pipe that narrows. The volume flow rate (Q) is the cross-sectional area of the pipe (A) multiplied by the velocity (v), so Q = A × v. Say the area at point 1 is larger than the area at point 2.

Because the same volume of liquid must pass every point in the pipe each second, the velocity at point 2 must be higher than at point 1. The narrowing pipe speeds the flow up, and by Bernoulli's principle the pressure at point 2 drops. That reduced pressure, or vacuum, at point 2 is what an eductor uses for suction.

How An Ejector Works In Ships ?

The motive fluid, usually seawater from a fire or general service pump, or compressed air, flows through the nozzle (3) and on through the diffuser (2), as shown in the diagram. Once the motive fluid reaches the required pressure and flow, the eductor starts to draw from the suction side.

There are normally valves on the motive fluid inlet, the discharge and the suction of the ejector. To operate it:

  • Open the discharge valve, usually overboard, and the motive fluid inlet valve.
  • Start the pump that supplies the motive fluid (usually a fire pump) and adjust it to the pressure the ejector needs. The pressure required depends on the discharge head.
  • Then open the suction valve so the ejector draws from the compartment being pumped.
  • Do not open the suction valve until the motive pressure has been established. Otherwise seawater can flow back through the suction into the compartment.
  • When stopping, close the suction valve first and then stop the motive fluid, for the same reason.

Typical design figures for a ship's bilge ejector are:

  • Motive fluid pressure: 7 kg/cm2
  • Motive fluid flow: 20 m3/h
  • Suction head: -7 mAq
  • Suction capacity: 5 m3/h
  • Discharge head: 6 mAq
  • Weight: 20 kg

Performance Curve

The performance curve shows how suction capacity changes with motive pressure at a given discharge head. For example, with the discharge head held at 6 mAq, the ejector draws 3 m3/h at a motive pressure of 5 kg/cm2 and 5 m3/h at 7 kg/cm2. Raising the motive pressure above the design pressure does not increase suction capacity beyond the design figure, but lowering it below the design pressure reduces suction.

A higher discharge head, or higher back pressure, also reduces suction.

Marine Ejector Maintenance and Troubleshooting

Nozzle or Throat Clogged

The most common cause of ejector trouble is debris blocking the nozzle or throat. Remove it with something soft, such as a piece of wood. Hard or sharp tools can scratch the nozzle or throat and permanently spoil the ejector's performance.

Low Drive Pressure

If the motive pressure falls below the specified value, the ejector can lose suction, or motive fluid can flow back into the suction side.

High Back Pressure

If the back pressure at the discharge rises, suction drops off sharply. Increasing the motive fluid flow or pressure can offset this to some extent, so keep an eye on the discharge pressure whenever the ejector is running.

Design Features and Assembly

An ejector consists of a cast iron, alloy or stainless steel body, the motive fluid nozzle assembly, a converging inlet, screws, sealing O-rings, a suction connection, a suction chamber, a diffuser and an outlet.

A conical nozzle sits inside the suction chamber, aligned so the jet leaves it axially and shoots straight into the diffuser.

The suction connection enters the chamber around the nozzle and carries in whatever liquid is being pumped out of the space.

The motive fluid enters through the nozzle. The high-speed jet drags the surrounding liquid along with it, and the diffuser then slows the mixture down, recovering pressure so it can be discharged against the required head.

Applications of Ejectors in Ships

  • Creating the vacuum in fresh water generators
  • Vacuum toilet systems
  • Priming systems for centrifugal pumps
  • Foam inductors in fire fighting systems
  • Pumping water out of the bosun's store, chain lockers and similar spaces
  • Stripping systems used with Framo cargo and ballast pumps